BRRQR - WHITE PLAS-TITE, 515

  • MSDS: BRRQR
  • Manufacturer: DBA PRODUCTS CO INC
  • Product Name: WHITE PLAS-TITE, 515
  • National Stock Number: 8010-00N015920
Product Identification

Product ID:WHITE PLAS-TITE, 515
MSDS Date:10/14/1987
FSC:8010
NIIN:00N015920
MSDS Number: BRRQR

Responsible Party
DBA PRODUCTS CO INC
22 SKOKIE HIGHWAY
LAKE BLUFF, IL 60044
US

Emergency Phone: 312-234-8100

Info Phone: 312-234-8100

Cage: 60443

Contractor
DBA PRODUCTS CO INC
LAKE BLUFF, IL 60044 US

Telephone: (708) 234-8100

Cage: 60443

Ingredients

WHILE DRYING/BAKING THIS PRODUCT MUST BE PROPERLY

RTECS: 9999999ZZ


ACETIC ACID, ISOBUTYL ESTER; (ISOBUTYL ACETATE). VP

CAS: 110-19-0

RTECS: AI4025000

Fraction By Weight: >5%

OSHA PEL 150 PPM

ACGIH TLV: 150 PPM

EPA Report Quantity: 5000 LBS

DOT Report Quantity: 5000 LBS


8@20C

CAS: 123-86-4

RTECS: AF7350000

Fraction By Weight: >5%

OSHA PEL 150 PPM;200 PPM STEL

ACGIH TLV: 150 PPM;200 PPM STEL

EPA Report Quantity: 5000 LBS

DOT Report Quantity: 5000 LBS


100@20C

CAS: 67-56-1

RTECS: PC1400000

Fraction By Weight: >5%

OSHA PEL S,200PPM/250STEL

ACGIH TLV: S,200PPM/250STEL; 93

EPA Report Quantity: 5000 LBS

DOT Report Quantity: 5000 LBS


8@20C

CAS: 67-63-0

RTECS: NT8050000

Fraction By Weight: >7%

OSHA PEL 400 PPM;500 PPM STEL

ACGIH TLV: 400 PPM;500 PPM STEL


38@20C

CAS: 108-88-3

RTECS: XS5250000

Fraction By Weight: >4%

OSHA PEL 200 PPM/150 STEL

ACGIH TLV: 50 PPM; 9293

EPA Report Quantity: 1000 LBS

DOT Report Quantity: 1000 LBS


NITROCELLULOSE

CAS: 9004-70-0

RTECS: QW0970000

Fraction By Weight: >15%

OSHA PEL N/K

ACGIH TLV: N/K


TITANIUM OXIDE; (TITANIUM DIOXIDE)

CAS: 13463-67-7

RTECS: XR2275000

Fraction By Weight: >6%

OSHA PEL 15 MG/M3 TDUST

ACGIH TLV: 10 MG/M3 TDUST; 9293


ETHANOL, 2-ETHOXY-, ACETATE; (CELLUSOLVE ACETATE). VP

CAS: 111-15-9

RTECS: KK8225000

Fraction By Weight: >9%

OSHA PEL 100 PPM, S

ACGIH TLV: 5 PPM, S


2-PENTANONE,4-METHYL-; (METHYL ISOBUTYL KETONE).VP

CAS: 108-10-1

RTECS: SA9275000

Fraction By Weight: >5%

OSHA PEL 100 PPM/75 STEL

ACGIH TLV: 50 PPM/75 STEL; 9293

EPA Report Quantity: 5000 LBS

DOT Report Quantity: 5000 LBS


ON NAVY LIST OF OCCUP REPROD HAZ. SEEK

RTECS: 9999999ZZ


HAZ LIST INFO & SAFE HNDLG & EXPOS RECOM. NIOSH

RTECS: 9999999ZZ


WORKPLACE AS HAVING POTNTL TO CAUSE ADVERSE REPROD

RTECS: 9999999ZZ


REMOVE W/INERT ABSORB. USE ONLY NONSPARKING

RTECS: 9999999ZZ


FOR DISP. PVNT CONTAM OF SEWERS, STREAMS, &

RTECS: 9999999ZZ


IN CONFINED AREAS USE A NIOSH/MSHA APPRVD

RTECS: 9999999ZZ


LIM STATED. REMOVE DECOMP PROD THAT ARE GENERATED

RTECS: 9999999ZZ


70@20C

CAS: 78-93-3

RTECS: EL6475000

Fraction By Weight: > 3%

OSHA PEL 200 PPM;300 PPM STEL

ACGIH TLV: 200 PPM;300 PPM STEL

EPA Report Quantity: 5000 LBS

DOT Report Quantity: 5000 LBS

Hazards

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:NO Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:ACUTE: INGEST: CAN CAUSE GI IRRIT,
NAUS & VOMIT. ASPIR OF MATL INTO LUNGS MAY CAUSE PULM PNEUM WHICH
CAN BE FATAL. INHAL: ANESTH MAY CAUSE IRRIT OF NOSE & THROAT, &
ACUTE NERV SYS DEPRESS. CHARACT BY HDCH, DIZZ, CONFUSN, NAUS, &
UNCON. EYE: MAY CAUSE SEV IRRIT. SKIN: LIQ MATL MAY BE ABSORBED
THRU SKIN (EFTS OF OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT
Effects of Overexposure:HLTH HAZ:IN HARMFUL AMT. MAY CAUSE DEFAT &
IRRIT OF SKIN. CHRONIC: TOLUENE HAS BEEN FOUND TO CAUSE KIDNEY,
LUNG & SPLEEN DAM IN LAB ANIMALS. RPTD OVEREXP TO TOLUENE MAY CAUSE
LIVER DAM. RPTS HAVE ASSO C PRLNGD & RPTD OCCUP OVEREXP TO SOLV
W/PERM BRAIN & NERV SYS DAM. INTENTIONAL MISUSE BY DELIB CONC &
(SUPP DATA)
Medical Cond Aggravated by Exposure:TOLUENE HAS BEEN FOUND TO CAUSE
KIDNEY, LUNG AND SPLEEN DAMAGE IN LABORATORY ANIMALS.

First Aid

First Aid:INGEST: CALL POIS CTL CTR, HOSP EMER ROOM/PHYS IMMED. DO NOT
INDUCE VOMIT. INHAL: REMOVE TO FRESH AIR. IF BRTHG IS STOPPED, GIVE
ARTF RESP. KEEP WARM & QUIET. GET MED ATTN IMMED. EYE: FLUSH W/LG
AMT O F WATER, LIFT LIDS OCCAS. CONTINUE FOR @ LST 15 MIN. GET MED
ATTN. SKIN: IMMED FLUSH CONTAMD AREA W/LG AMT OF WATER. REMOVE
CONTAMD CLTHG AS WATER IS APPLIED. GET MED ATTN IF IRRIT PERSISTS.

Fire Fighting

Flash Point Method:TCC
Flash Point:45F,7.2C
Extinguishing Media:USE NFPA CLASS B FIRE EXTING (CARBON DIOXIDE ALL
PURPOSE DRY CHEM/ALCOHOL FOAM) DESIGNED TO EXTING FLAMM (SUPP DATA)
Fire Fighting Procedures:NIOSH/MSHA APPRVD SCBA & FULL PROT EQUIP.
WATER MAY BE INEFTIVE, BUT MAY BE USED TO COOL EXPOSED CONTRS TO
PVNT PRESS BUILD-UP & POSS AUTO-IGNIT/ (SUPDAT)
Unusual Fire/Explosion Hazard:DURING EMER CNDTNS, OVEREXP TO DECOMP
PROD MAY CAUSE A HLTH HAZ. SYMP MAY NOT BE IMMED APPARENT. OBTAIN
MED ATTN. WARNING: FLAMMABLE.

Accidental Release

Spill Release Procedures:KEEP SPECTATORS AWAY. ELIM ALL SOURCES OF
IGNIT (FLAMES, HOT SURF, & SOURCE OF ELEC, STATIC/FRICTIONAL
SPARKS). DIKE & CNTN SPILL W/INERT MATL (SAND, EARTH, SAWDUST, OR
VERMICULITE). TRANSFER LIQ TO COVERED METAL CONTRS FOR
RECOVERY/DISP/(ING 14)
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:DO NOT STORE ABOVE 95F. STORE LARGE
QTY IN COMPLIANCE WITH OSHA 29 CFR 1910.106.
Other Precautions:DO NOT TAKE INTERNALLY. CLOSE CONTAINEER AFTER EACH
USE. EMPTY CONTAINERS MUST NOT BE WASHED & RE-USED FOR ANY PURPOSE.
CONTAINERS SHOULD BE GROUNDED AND BONDED TO RECYCLING CONTAINER. DO
NOT WELD, BR AZE/CUT ON EMPTY CONTAINER.

Exposure Controls

Respiratory Protection:WHEN COATING IN OPEN/WELL VENTD AREAS, USE
NIOSH/MSHA APPRVD MECH FILTER RESP TO REMOVE VAPS. IN RESTRICTED
VENT AREA USE NIOSH/MSHA APPRVD PAINT SPRAY (COMBINATION CHEM
CARTRIDGE/MECH FILTER) RESP TO REMOVE SPRAY MIST & ORG VAPS.(ING
16)
Ventilation:PROVIDE GEN DILUT & LOC EXHAUST VENT IN SUFFICIENT VOL &
PATTERN TO KEEP CONC OF HAZ INGRED BELOW LOWEST EXPOS (ING 17)
Protective Gloves:SOLVENT IMPERMEABLE GLOVES.
Eye Protection:CHEMICAL WORKERS GOGGLES .
Other Protective Equipment:EYE WASH FACILITY, SAFETY SHOWER.
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
EXTING MEDIA:LIQ FIRES. POLYMER FOAM IS PREFERRED FOR LG FIRES. FIRE
FIGHT PROC:EXPLO WHEN EXPOSED TO EXTREME HEAT. IF WATER IS USED,
FOG NOZZ ARE PREF. EFTS OF OVEREXP:INHALING CONTENTS MAY BE HARMFU
L/FATAL. TOLUENE HAS BEEN FOUND TO CAUSE KIDNEY, LUNG & SPLEEN DAM
IN LAB ANIMALS. NOTE. TOLUENE, CAS # 108-88-3(ING 11)

Chemical Properties

HCC:F3
Boiling Pt:B.P. Text:>149F,>65C
Vapor Pres:SEE INGRED
Vapor Density:HVR/AIR
Spec Gravity:0.829
Evaporation Rate & Reference:FASTER THAN ETHER
Appearance and Odor:NONE SPECIFIED BY MANUFACTURER.

Stability

Stability Indicator/Materials to Avoid:YES
STRONG ACIDS/ALKALINE MATL. ACETYL CHLORIDE. OXIDIZING MATERIAL.
Stability Condition to Avoid:EXCESSIVE HEAT AND SOURCES OF IGNITION.
Hazardous Decomposition Products:BURNING, INCL WHEN HEATED, WILL PRDCE
SMOKE/CARBON MONOXIDE & CARBON DIOXIDE IN ADDN OXIDE OF NITROGEN
MAY BE GENERATED.

Disposal

Waste Disposal Methods:DISPOSE I/A/W FED, ST & LOC REGS. INCIN ONLY IN
EPA PERMITTED FACILITY. DO NOT INCIN CLSD CONTRS. OBSERVE PREC FOR
DISP OF FLAMM MATL. CONTAMD ABSORB MAY BE DISPOSED IN A HAZ WASTE
LANDFILL. DISPOSE O NLY I/A/W FED, ST & LOC REG.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.